Top Quality Disposable Endoscopic Loop Net - Bougie dilator – Chenmao
Top Quality Disposable Endoscopic Loop Net - Bougie dilator – Chenmao Detail:
Characteristic
- 1.The dilator is made of medical-grade polymer materials with moderate hardness
- 2.The end cone is smooth,conductive to expansion,and less traumatic.
- 3.There is a developing ring at the head end,which can be positioned more accurately under X-way.
- 4.Comes with a portable outer box for easy transportation .
Product Properties
1.The surface of bougie shall be smooth without burr, as well as the front con.
2.The guide wire body shall pass through the inner hole of the bougie without blocking.
3.The bougie with development rings shall have X-ray development markings.
4.Appearance (turbidity, color) : colorless transparent, visually no foreign body.
Specifications
Model Number |
Diameter(mm) |
Length(mm) |
GM-BD-A1-05-850 |
5 |
850 |
GM-BD-A1-06-850 |
6 |
850 |
GM-BD-A1-07-850 |
7 |
850 |
GM-BD-A1-08-850 |
8 |
850 |
GM-BD-A1-09-850 |
9 |
850 |
GM-BD-A1-10-850 |
10 |
850 |
GM-BD-A1-11-850 |
11 |
850 |
GM-BD-A1-12-850 |
12 |
850 |
GM-BD-A1-13-850 |
13 |
850 |
GM-BD-A1-14-850 |
14 |
850 |
GM-BD-A1-15-850 |
15 |
850 |
GM-BD-A1-16-850 |
16 |
850 |
GM-BD-A1-17-850 |
17 |
850 |
GM-BD-A1-18-850 |
18 |
850 |
GM-BD-A1-19-850 |
19 |
850 |
GM-BD-A1-20-850 |
20 |
850 |
Disposable cytology brush structure diagram
Scope of application
The disposable bougie is indicated for patients with esophageal and cardiac stricture dilation therapy.
Contraindications
1. The device shall be thoroughly sterilized before use.
2. According to X-ray or endoscopic observation of the stenosis of the esophagus or cardia of the patient during the application, the bougie with a diameter slightly larger than that of the narrow site of patient shall be selected.
3. Under X-ray monitoring, the guide wire shall be first inserted through the hole of the gastroscope until the soft spring at the front of the guide wire was in the stomach cavity (it can be judged whether it is in the stomach from the bending shape of the soft spring), and the guide wire shall be removed from the gastroscope and retained.
4. The bougie is slid along the guide wire through the narrow part of the patient to play an expansion role. The diameter of the bougie shall be selected from small to large and gradually expanded.
Instructions For Use
Product detail pictures:



Related Product Guide:
Global Biopsy Forceps Market In-depth Insights, Revenue Details, and Other Vital Information & Forecast Till 2028 | Cylindrical Anoscope
Global Urology Devices Market Set to Grow at Healthy CAGR By 2026 | Medtronic, Siemens AG, Baxter, B. Braun Melsungen AG, Fresenius Medical Care AG & Co. KGaA, Karl Storz GmbH & Co. Kg, Stryker, Olympus Corporation, Cook Group, C.R. Bard, Inc. | Cytology Brush
Our firm aims to operating faithfully, serving to all of our shoppers , and working in new technology and new machine consistently for Top Quality Disposable Endoscopic Loop Net - Bougie dilator – Chenmao, The product will supply to all over the world, such as: Detroit , Swaziland , Mexico , Our factory insists on the principle of "Quality First, Sustainable Development", and takes "Honest Business, Mutual Benefits" as our developable goal. All members sincerely thanks for all old and new customers' support. We will keep working hard and offering you the highest-quality products and service.Thanks.

This is a very professional and honest Chinese supplier, from now on we fell in love with the Chinese manufacturing.