Quality Inspection for Endoscopy Loop Net - Bougie dilator – Chenmao
Quality Inspection for Endoscopy Loop Net - Bougie dilator – Chenmao Detail:
Characteristic
- 1.The dilator is made of medical-grade polymer materials with moderate hardness
- 2.The end cone is smooth,conductive to expansion,and less traumatic.
- 3.There is a developing ring at the head end,which can be positioned more accurately under X-way.
- 4.Comes with a portable outer box for easy transportation .
Product Properties
1.The surface of bougie shall be smooth without burr, as well as the front con.
2.The guide wire body shall pass through the inner hole of the bougie without blocking.
3.The bougie with development rings shall have X-ray development markings.
4.Appearance (turbidity, color) : colorless transparent, visually no foreign body.
Specifications
Model Number |
Diameter(mm) |
Length(mm) |
GM-BD-A1-05-850 |
5 |
850 |
GM-BD-A1-06-850 |
6 |
850 |
GM-BD-A1-07-850 |
7 |
850 |
GM-BD-A1-08-850 |
8 |
850 |
GM-BD-A1-09-850 |
9 |
850 |
GM-BD-A1-10-850 |
10 |
850 |
GM-BD-A1-11-850 |
11 |
850 |
GM-BD-A1-12-850 |
12 |
850 |
GM-BD-A1-13-850 |
13 |
850 |
GM-BD-A1-14-850 |
14 |
850 |
GM-BD-A1-15-850 |
15 |
850 |
GM-BD-A1-16-850 |
16 |
850 |
GM-BD-A1-17-850 |
17 |
850 |
GM-BD-A1-18-850 |
18 |
850 |
GM-BD-A1-19-850 |
19 |
850 |
GM-BD-A1-20-850 |
20 |
850 |
Disposable cytology brush structure diagram
Scope of application
The disposable bougie is indicated for patients with esophageal and cardiac stricture dilation therapy.
Contraindications
1. The device shall be thoroughly sterilized before use.
2. According to X-ray or endoscopic observation of the stenosis of the esophagus or cardia of the patient during the application, the bougie with a diameter slightly larger than that of the narrow site of patient shall be selected.
3. Under X-ray monitoring, the guide wire shall be first inserted through the hole of the gastroscope until the soft spring at the front of the guide wire was in the stomach cavity (it can be judged whether it is in the stomach from the bending shape of the soft spring), and the guide wire shall be removed from the gastroscope and retained.
4. The bougie is slid along the guide wire through the narrow part of the patient to play an expansion role. The diameter of the bougie shall be selected from small to large and gradually expanded.
Instructions For Use
Product detail pictures:



Related Product Guide:
Global Prostate Biopsy Forceps Market 2019 – 2025 Amecath, Endo-Flex, Maxer Endoscopy, Bard Medical, UROMED, COOK Medical | Cytology Brush
Latin America Gynaecological Devices Market 2019 Ongoing Trends and Recent Developments | Hemorrhoidal Circular Stapler
The corporation upholds the philosophy of "Be No.1 in high quality, be rooted on credit rating and trustworthiness for growth", will continue to serve outdated and new consumers from home and overseas whole-heatedly for Quality Inspection for Endoscopy Loop Net - Bougie dilator – Chenmao, The product will supply to all over the world, such as: Borussia Dortmund , Orlando , Vancouver , With a team of experienced and knowledgeable personnel, our market covers South America, the USA, the Mid East, and North Africa. Many customers have become our friends after good cooperation with us. If you have the requirement for any of our goods, make sure you contact us now. We're looking forward to hearing from you soon.

As a veteran of this industry, we can say that the company can be a leader in the industry, select them is right.