Manufacturer ofAnoscope Surgery Instruments - Intestinal Stent – Chenmao

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We have now numerous great personnel members good at advertising, QC, and working with kinds of troublesome dilemma from the creation course of action for Endoscopy Retrieval Balloon Catheter , Biopsy Forceps , Nasal Spray , We keep on with supplying integration alternatives for customers and hope to create long-term, steady, sincere and mutual advantageous interactions with consumers. We sincerely anticipate your check out.
Manufacturer ofAnoscope Surgery Instruments - Intestinal Stent – Chenmao Detail:

Characteristics:
Continued gentle radial tensile force,effectively expands the stenosis,reducing the patients’ discomfort.
Imaging markers of the stents are clear visible under image equipment.Positioning is more accurate.
Conform to the pylorus of physiological anatomy port design
Introducer system sketch:
otw
specification table:

Stent diameter(mm)

(mm)

Port diameter
(middle/near-end)

Length(mm)

Specification of Introducer system

(Pipe diameter Fr × effective working length   mm)

Head end shape

18

18/45

60/80

18Fr× 1350

Single ball-single horn

20

20/45

60/80

18Fr× 1350

18

18/45

60/80

18Fr× 1350

Double horns

20

20/45

60/80

18Fr× 1350

18

18/45

60/80

18Fr× 1350

Double balls

20

20/45

60/80

18Fr× 1350

 

Stent diameter(mm)

Port diameter (middle/near-end)

Length(mm)

Specification of Introducer system

(Pipe diameter Fr × effective working length   mm)

18

18/25

60/80/100/120

18Fr× 1300(OTW)

20

20/25

60/80/100/120

18Fr× 1300(OTW)

18

18/25

60/80/100

10Fr× 1800(TTS)

20

20/25

60/80/100

10Fr× 1800(TTS)

 

Stent diameter(mm)

Port diameter(middle/near-end)

Length(mm)

Specification of Introducer system

(Pipe diameter Fr × effective working length   mm)

25

25/36

60/80/100

24Fr× 1000(OTW)

28

28/36

60/80/100

24Fr× 1000(OTW)

30

30/36

60/80/100

24Fr× 1000(OTW)

25

25/36

60/80/100

10Fr× 2400(TTS)

28

28/36

60/80/100

10Fr× 2400(TTS)

30

30/36

60/80/100

10Fr× 2400(TTS)

 

Stent diameter(mm)

Port diameter(middle/near-end)

Length(mm)

Specification of Introducer system

(Pipe diameter Fr × effective working length   mm)

28

28/36

60/80/100

24Fr× 1000(OTW)

30

30/36

60/80/100

24Fr× 1000(OTW)


Product detail pictures:

Manufacturer ofAnoscope Surgery Instruments -
 Intestinal Stent – Chenmao detail pictures


Related Product Guide:
Seeded Amplification of Chronic Wasting Disease Prions in Nasal Brushings and Recto-anal Mucosa-Associated Lymphoid Tissues from Elk by Real-Time Quaking-Induced Conversion | Cytology Brush
Mining Tire Market Report – A Complete Overview of Market Segments and the Regional Outlook of Mining Tire Industry | Hemorrhoidal Circular Stapler

Our aim would be to fulfill our shoppers by offering golden company, very good value and good quality for Manufacturer ofAnoscope Surgery Instruments - Intestinal Stent – Chenmao, The product will supply to all over the world, such as: Argentina , Panama , Pakistan , We have the best products and professional sales and technical team.With the development of our company, we are able to provide customers best products, good technical support, perfect after-sales service.