High Performance Medical Human Implant Intestinal Stent Surgical Self Expandable Metal Colon Stent

Short Description:

Usage
Used for malignant lesions caused by gastric outlet stenosis or obstruction,
suitable for ministry of pyloric stenosis .


Product Detail

Product Tags

We’re commitment to offer you the competitive price ,remarkable products excellent, also as fast delivery for High Performance Medical Human Implant Intestinal Stent Surgical Self Expandable Metal Colon Stent, Never-ending improvement and striving for 0% deficiency are our two main good quality policies. Should you need anything, do not hesitate to call us.
We’re commitment to offer you the competitive price ,remarkable products excellent, also as fast delivery for Human Implant, Intestinal Stent Nitinol, Self Expandable Metal Stent, We follow up the career and aspiration of our elder generation, and we’ve been eager to open up a new prospect in this field, We insist on “Integrity, Profession, Win-win Cooperation”, because we now have a strong backup, that are excellent partners with advanced manufacturing lines, abundant technical strength, standard inspection system and good production capacity.
Characteristics:
Continued gentle radial tensile force,effectively expands the stenosis,reducing the patients’ discomfort.
Imaging markers of the stents are clear visible under image equipment.Positioning is more accurate.
Conform to the pylorus of physiological anatomy port design
Introducer system sketch:
otw
specification table:

Stent diameter(mm)

(mm)

Port diameter
(middle/near-end)

Length(mm)

Specification of Introducer system

(Pipe diameter Fr × effective working length   mm)

Head end shape

18

18/45

60/80

18Fr× 1350

Single ball-single horn

20

20/45

60/80

18Fr× 1350

18

18/45

60/80

18Fr× 1350

Double horns

20

20/45

60/80

18Fr× 1350

18

18/45

60/80

18Fr× 1350

Double balls

20

20/45

60/80

18Fr× 1350

 

Stent diameter(mm)

Port diameter (middle/near-end)

Length(mm)

Specification of Introducer system

(Pipe diameter Fr × effective working length   mm)

18

18/25

60/80/100/120

18Fr× 1300(OTW)

20

20/25

60/80/100/120

18Fr× 1300(OTW)

18

18/25

60/80/100

10Fr× 1800(TTS)

20

20/25

60/80/100

10Fr× 1800(TTS)

 

Stent diameter(mm)

Port diameter(middle/near-end)

Length(mm)

Specification of Introducer system

(Pipe diameter Fr × effective working length   mm)

25

25/36

60/80/100

24Fr× 1000(OTW)

28

28/36

60/80/100

24Fr× 1000(OTW)

30

30/36

60/80/100

24Fr× 1000(OTW)

25

25/36

60/80/100

10Fr× 2400(TTS)

28

28/36

60/80/100

10Fr× 2400(TTS)

30

30/36

60/80/100

10Fr× 2400(TTS)

 

Stent diameter(mm)

Port diameter(middle/near-end)

Length(mm)

Specification of Introducer system

(Pipe diameter Fr × effective working length   mm)

28

28/36

60/80/100

24Fr× 1000(OTW)

30

30/36

60/80/100

24Fr× 1000(OTW)


  • Previous:
  • Next:

  • Related Products