Factory selling Spray Tube - Trachea Bronchus Stent – Chenmao
Factory selling Spray Tube - Trachea Bronchus Stent – Chenmao Detail:
Characteristics:
Continued gentle radial tensile force,effectively expands the stenosis,reducing the patients’ discomfort.
Imaging markers of the stents are clear visible under image equipment.Positioning is more accurate.
With bundled transmission mode.
Introducer system sketch:
specification table:
Stents diameter(mm) |
Length(mm) |
Description |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
16 |
40/50/60 |
1.
|
24r× 700 |
18 |
40/50/60 |
24r× 700 |
|
20 |
40/50/60 |
24r× 700 |
|
22 |
40/50/60 |
24r× 700 |
J- Trachea/Bronchus stent
Usage :
Used to ease of malignant lesions caused by primary tracheal and bronchial stenosis .
Characteristics:
Continued gentle radial tensile force,effectively expands the stenosis,reducing the patients’ discomfort.
Full compliance with the anatomical knot of tracheal bifurcation .
Imaging markers of the stents are clear visible under image equipment.Positioning is more accurate.
Introducer system sketch:
specification table
Stents diameter(mm) |
Length(mm) |
Description |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
18 |
40/50/60/70/80 |
1. Regular size of left bronchus –Diameter:12/14mm,Length: 20/25/30/35mm 2. Regular size of right bronchus –Diameter:12/14mm, Length:10/15/20/25mm
|
push-based introducer system:8×600 |
20 |
40/50/60/70/80 |
||
22 |
40/50/60/70/80 |
Product detail pictures:



Related Product Guide:
মলদ্বার না কেটে পাইলস অপারেশন | Wound Closure Device
Globally Micromanipulators Market Expected To Reach Multi Billion Dollars By 2024 | Wound Closure Device
Our primary intention should be to offer our clientele a serious and responsible enterprise relationship, delivering personalized attention to all of them for Factory selling Spray Tube - Trachea Bronchus Stent – Chenmao, The product will supply to all over the world, such as: Uruguay , Sierra Leone , Bahamas , We have more than 100 works in the plant, and we also have a 15 guys work team to service our customers for before and after sales. Good quality is the key factor for the company to stand out from other competitors. Seeing is Believing, want more information? Just trial on its products!

This company has the idea of "better quality, lower processing costs, prices are more reasonable", so they have competitive product quality and price, that's the main reason we chose to cooperate.