100% Original Mouthpiece Bite Block - Intestinal Stent – Chenmao
100% Original Mouthpiece Bite Block - Intestinal Stent – Chenmao Detail:
Characteristics:
Continued gentle radial tensile force,effectively expands the stenosis,reducing the patients’ discomfort.
Imaging markers of the stents are clear visible under image equipment.Positioning is more accurate.
Conform to the pylorus of physiological anatomy port design
Introducer system sketch:
specification table:
Stent diameter(mm) |
(mm) Port diameter |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
Head end shape |
18 |
18/45 |
60/80 |
18Fr× 1350 |
Single ball-single horn |
20 |
20/45 |
60/80 |
18Fr× 1350 |
|
18 |
18/45 |
60/80 |
18Fr× 1350 |
Double horns |
20 |
20/45 |
60/80 |
18Fr× 1350 |
|
18 |
18/45 |
60/80 |
18Fr× 1350 |
Double balls |
20 |
20/45 |
60/80 |
18Fr× 1350 |
Stent diameter(mm) |
Port diameter (middle/near-end) |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
18 |
18/25 |
60/80/100/120 |
18Fr× 1300(OTW) |
20 |
20/25 |
60/80/100/120 |
18Fr× 1300(OTW) |
18 |
18/25 |
60/80/100 |
10Fr× 1800(TTS) |
20 |
20/25 |
60/80/100 |
10Fr× 1800(TTS) |
Stent diameter(mm) |
Port diameter(middle/near-end) |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
25 |
25/36 |
60/80/100 |
24Fr× 1000(OTW) |
28 |
28/36 |
60/80/100 |
24Fr× 1000(OTW) |
30 |
30/36 |
60/80/100 |
24Fr× 1000(OTW) |
25 |
25/36 |
60/80/100 |
10Fr× 2400(TTS) |
28 |
28/36 |
60/80/100 |
10Fr× 2400(TTS) |
30 |
30/36 |
60/80/100 |
10Fr× 2400(TTS) |
Stent diameter(mm) |
Port diameter(middle/near-end) |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
28 |
28/36 |
60/80/100 |
24Fr× 1000(OTW) |
30 |
30/36 |
60/80/100 |
24Fr× 1000(OTW) |
Product detail pictures:

Related Product Guide:
Global Cytology Brush Market Ratio 2019 Accurate Developed By 2028 | Cylindrical Anoscope
Cytology Brush Market Report Provide the Development Strategies Adopted by Key Industry Players to Understand Competitive Scenario of the Global Cytology Brush Market | Hemorrhoidal Circular Stapler
From the past few years, our firm absorbed and digested sophisticated technologies equally at home and abroad. Meanwhile, our organization staffs a group of experts devoted into the growth of 100% Original Mouthpiece Bite Block - Intestinal Stent – Chenmao, The product will supply to all over the world, such as: Israel , Southampton , Sevilla , we rely on own advantages to build a mutual-benefit commerce mechanism with our cooperative partners. As a result, we have gained a global sales network reaching the Middle East, Turkey, Malaysia and Vietnamese.

It's really lucky to find such a professional and responsible manufacturer, the product quality is good and delivery is timely, very nice.